The Pumping Up Phenomenon of Double-Stage Bubble Pump with Water and Aqueous LiBr Solution

Hongtao Gao, Guotuan Ma and Wei Yang
Corresponding Author:  Hongtao Gao 

Key words:  Absorption refrigeration, double-stage bubble pump, pressure difference, pump-up phenomenon, start-up time , ,
Vol. 5 , (06): 2107-2112
Submitted Accepted Published
July 27, 2012 September 03, 2012 February 21, 2013
Abstract:

The double-stage bubble pump, using thermal energy as driving force to transport the solution, can replace the mechanical solution pump in the double-effect lithium bromide absorption chiller. By building a bench, a lot of experimental research and analysis were conducted with water and different concentrations of lithium bromide solution as the working fluid of the bubble pump. The first-stage bubble pump in the experiment pumps up by the external heat source. The heat for driving the second-stage bubble pump is provided by refrigerant steam produced from the first-stage bubble pump. The experiment data shows that the heating of refrigerant vapor is only one of the elements of pump-up phenomenon. Another is that the intermediate solution flashes to vapor to become bubbles. The pump-up phenomenon of double-stage bubble pump has much to do with the pressure difference of intermediate solution and first-stage refrigerant vapor. With water as the working fluid, when the pressure difference between refrigerant vapor and the intermediate liquefied refrigerant is 3.5-3.9 kPa, the bubble pump can pump up and run for some time and the start-up time decreases with the driving head. When the working fluid is lithium bromide solution, the pressure difference of the double-stage bubble pump increases with the solution concentration and is bigger than that of water. The start-up time increases with the concentrations of lithium bromide solution within the range of 45.5 to 54% and decreases within the range of 54-59.5%. The start-up time is largest at 54% under this experimental condition. The experimental result is also compared with the single-stage bubble pump. The start-up time of double-stage bubble pump decreases with the driving height, which is contrary to the single-stage bubble pump.
Abstract PDF HTML
  Cite this Reference:
Hongtao Gao, Guotuan Ma and Wei Yang, 2013. The Pumping Up Phenomenon of Double-Stage Bubble Pump with Water and Aqueous LiBr Solution.  Research Journal of Applied Sciences, Engineering and Technology, 5(06): 2107-2112.
    Advertise with us
 
ISSN (Online):  2040-7467
ISSN (Print):   2040-7459
Submit Manuscript
   Current Information
   Sales & Services
   Contact Information
  Executive Managing Editor
  Email: admin@maxwellsci.com
  Publishing Editor
  Email: support@maxwellsci.com
  Account Manager
  Email: faisalm@maxwellsci.com
  Journal Editor
  Email: admin@maxwellsci.com
  Press Department
  Email: press@maxwellsci.com
Home  |  Contact us  |  About us  |  Privacy Policy
Copyright © 2009. MAXWELL Science Publication, a division of MAXWELLl Scientific Organization. All rights reserved