Retinopathy of Prematurity Vessel and Ridge Parameters Measurement by Unsupervised Algorithm

1S. Prabakar, 2K. Porkumaran, 3Parag K. Shah and 3V. Narendran
1Department of Electronics and Communication Engineering, Kathir College of Engineering, Coimbatore-641062, India
2N.G.P. Institute of Technology, Coimbatore-641048, India
3Department of Paediatric Retina and Ocular Oncology, Aravind Eye Hospitals, Coimbatore, India
Research Journal of Applied Sciences, Engineering and Technology  2014  17:3499-3513
http://dx.doi.org/10.19026/rjaset.7.702  |  © The Author(s) 2014
Received: October 19, 2013  |  Accepted: October 28, 2013  |  Published: May 05, 2014

Abstract

The Retinopathy of Prematurity (ROP) is an ocular pathological disorder of the retinal blood vessels in premature infants and low birth weight infants. It is essential that those caring for premature infants should know who is at risk of ROP and their severity stage. It is also important that when screening must begin and how often these infants need to be examined otherwise the progression lead most severe stage and can cause blindness. The contrast stretching method has been utilized to enhance the ROP color image. Then an automatic method Isotropic Un-decimated Wavelet Transform (IUWT) has been proposed to extract the abnormal retinal blood vessel and measure its width and tortuosity. The ridge formation of this pathological disorder has also been obtained by the IUWT. The quantitative measurements of mean diameter, standard deviation, tortuosity, length of retinal blood vessel and ridge have been considered and computed the exact severity stage of ROP. The effectiveness of the proposed method has been verified through machine vision techniques and the results obtained are encouraged by experts. Automatic ROP screening system comprises several advantages, like a substantial time reduction of ophthalmologists in diagnosis, a non ophthalmologist can provide stage of ROP, improving the sensitivity of the test and a better accuracy in diagnosis.

Keywords:

Premature infants, retinal vessel, retinopathy of prematurity, ROP screening, un-decimated wavelet transform,


References

  1. Antoine, J.P. and R. Murenzi, 1994. Two dimensional wavelet analysis in image processing. Physicalia Mag., 16: 105-134.
  2. Benson L., SY, Yongsheng Gao and Alan Wee-Chung Liew, 2010. "General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling," IEEE Transactions on Medical Imaging, 29(7): 1369-1381.
    CrossRef    PMid:20304729    
  3. Conor, H., J. Flynn, M.O. Keefe and M. Cahill, 2002. Characteriztion of changes in blood vessel width and tortuosity in retinopathy of prematurity using image analysis. Med. Image Anal., 6(4): 407-429.
    CrossRef    
  4. Carmen A.L. and T. Domenico, 2011. "Automatic Unsupervised Segmentation of Retinal Vessels Using Self-Organizing Maps and K-Means Clustering", Rizzo, R. and P.J.G. Lisboa, Springer Verlag LNBI 6685, pp: 263-274.
  5. Dutilleux, P., 1989. An implementation of the 'algorithme `a trous' to compute the wavelet transform. In: Combes, J.M., A. Grossmann and P.H. Tchamitchian (Eds.), Wavelets: Time-frequency Methods and Phase-space. Springer, New York.
    CrossRef    
  6. Early Treatment of Retinopathy of Prematurity Cooperative Group, 2003. Revised indications for the treatment of retinopathy of prematurity. Arch Ophthalmol., 121: 1684-96.
    CrossRef    PMid:14662586    
  7. Fraz, M.M., P. Remagnino, A. Hoppe, B. Uyyanonvara, A.R. Rudnicka, C.G. Owen and S.A. Barman, 2012. Blood vessel segmentation methodologies in retinal images-A survey. Comput. Methods Programs Biomed., 108: 407-433.
    CrossRef    PMid:22525589    
  8. Gwenole, Q., M. Lamard, P.M. Josselin and G. Cazuguel, 2008. Optimal wavelet transform for the detection of micro aneurysms in retina photographs. IEEE T. Med. Imaging, 27(9): 1230-1241.
    CrossRef    PMid:18779064 PMCid:PMC2567825    
  9. International Committee for the Classification of Retinopathy of Prematurity, 2005. The international classification of retinopathy of prematurity revisited. Arch Ophthalmol., 123: 991-999.
    CrossRef    PMid:16009843    
  10. Julien, J., D.K. Wallace and S. Aylward, 2003. Quantification of retinopathy of prematurity via vessel segmentation. Medical Image Computing and Computer assisted intervention-MICCAI 2003. Springer Lect. Notes Comput. Sci., 2879: 620-626.
  11. Kevin N. and K.P. Nayak, 2012. "A Review of Fundus Image Analysis for the Automated Detection of Diabetic Retinopathy", Journal of Medical Imaging and Health Informatics, 2(3): 258-265(8).
  12. Lam, B.S.Y. and Y. Hong, 2008. A novel vessel segmentation algorithm for pathological retina images based on the divergence of vector fields. IEEE T. Med. Imaging, 27(2): 237-246.
    CrossRef    PMid:18334445    
  13. Lam, L., S.W. Lee and C.Y. Suen, 1992. Thinning methodologies-a comprehensive survey. IEEE T. Pattern Anal., 14: 869-885.
    CrossRef    
  14. Lassada, S., B. Uyyanovara, S.A. Barman and J. Jaruwat, 2004. Automated vessels detection on infant retinal images. Proceeding of International Conference on Control, Automation and Systems, pp: 321-325.
  15. Lee, E.T.Y., 1989. Choosing nodes in parametric curve interpolation. Comput. Aided Design, 21: 363-370.
    CrossRef    
  16. Michal S. and C.V. Stewart, 2005. "Retinal Vessel Extraction Using Multiscale Matched Filters, Con?dence And Edge Measures", Department of Computer Science, Rensselaer Polytechnic Institute, Troy, New York 12180-3590, Technical Report : 05-20.
  17. Michael F.C., E.S. Karen, Y.K. David, W. Lu, A.K. Steven, C. Osode, S. Justin and T.F. John, 2008. "Telemedical Diagnosis of Retinopathy of Prematurity. Intraphysician Agreement between Ophthalmoscopic Examination and Image-Based Interpretation", Ophthalmology; 115(7): 1222-1228.e3.
  18. Mounir, B., M. Johanne and C.C. Gerontis, 2008. Retinopathy of Prematurity.
    Direct Link
  19. Olivo-Marin, J.C., 2002. Extraction of spots in biological images using multistage products. Pattern Recogn., 35: 1989-1996.
    CrossRef    
  20. Phan T., T.H. Khan, AU, L. Young-Koo, L. Sungyoung and K. Tae-Seong, 2009. 'Vessel enhancement filter using directional filter bank', Computer Vision and Image Understanding, 113(1): 101-112.
    CrossRef    
  21. Parag, K.S., A. Saurabh, V. Narendran and N. Kalpana, 2011. Retinopathy of prematurity-the new challenge. Retina, 17(4): 23-27.
  22. Prabakar, S., K. Porkumaran, P.K. Shah and V. Narendran, 2012. Optimized Imaging Techniques to Detect and Screen the Stages of Retinopathy of Prematurity. In: Fabiio, S. (Ed.), Human-Centric Machine Vision, pp: 59-80. ISBN: 978-953-51-0563-3, Intech, DOI: 10.5772/26609.
    CrossRef    
  23. Peter B., S.C. Norman, M.J. Graham and C.M. Tim, 2012. 'Fast Retinal Vessel Detection and Measurement Using Wavelets and Edge Location Refinement', PLoS ONE, e32435, doi: 10.1371/ journal.pone.0032435, 7(3): 1-12.
  24. Rashmi, T. and B. Uyyanonvara, 2012. Curvature-based tortuosity evaluation for infant retinal images. J. Inform. Eng. Appl., 2(8): 9-18.
  25. Robert, K., S.J. Teper, W. Beata, W. Edward, M.K. Micha and W. Zygmunt, 2012. Fully automatic algorithm for the analysis of vessels in the angiographic Image of the eye fundus. Biomed. Eng. Online, 11: 35.
    CrossRef    PMid:22727245 PMCid:PMC3458903    
  26. Shankar, P.M., 1986. Speckle reduction in ultrasound B scans using weighted averaging in spatial compounding. IEEE T. Ultrason. Ferr., 33(6): 754-758.
    CrossRef    
  27. Starck, J.L., F. Murtagh and A. Bijaoui, 1998. Image Processing and Data Analysis: The Multistage Approach. Cambridge University Press, Cambridge.
    CrossRef    
  28. Starck, J.L. and F. Murtagh, 2001. Astronomical image and signal processing. IEEE Signal Proc. Mag., 18: 30-40.
    CrossRef    
  29. Starck, J.L. and F. Murtagh, 2002. Astronomical Image and Data Analysis. Springer-Verlag, New York.
    CrossRef    PMCid:PMC1370306    
  30. Starck J.L. and F. Murtagh, 2007. The undecorated wavelet decomposition and its reconstruction. IEEE T. Signal Proces., 16: 297-309.
  31. Shaeb B.S and P.K. Satya, 2008. "Automatic Detection of Exudates in Diabetic Retinopathy Using Morphological Segmentation and Fuzzy Logic", IJCSNS International Journal of Computer Science and Network Security, 8(12): 211-218.
  32. Vermeer, K.A., F.M. Vos, H.G. Lemij and A.M. Vossepoel, 2004. A model based method for retinal blood vessel detection. Comput. Biol. Med., 34: 209-219.
    CrossRef    
  33. William, E.H., G. Michael, C. Brad, K. Paul and M.R. Nelson, 1999. Measurement and classification of retinal vascular tortuosity. Int. J. Med. Inform., 53: 239-252.
    CrossRef    
  34. Wilson, C.M., K.D. Cocker, M.J. Moseley, C. Paterson, S.T. Clay, W.E. Schulenburg, M.D. Mills, A.L. Ells, K.H. Parker, G.E. Quinn, A.R. Fielder and J. Ng, 2008. Computerized analysis of retinal vessel width and tortuosity in premature infants. Invest Othalmol. Vis. Sci., 49: 3577-3585.
    CrossRef    PMid:18408177    
  35. Wittchow, K., 2003. Shared Liability for ROP Screening. OMIC Journal.P.3.
    Direct Link
  36. Xiayu X., 2012. "Automated delineation and quantitative analysis of blood vessels in retinal fundus image", Ph.D. Thesis, University of Iowa.

Competing interests

The authors have no competing interests.

Open Access Policy

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Copyright

The authors have no competing interests.

ISSN (Online):  2040-7467
ISSN (Print):   2040-7459
Submit Manuscript
   Information
   Sales & Services
Home   |  Contact us   |  About us   |  Privacy Policy
Copyright © 2024. MAXWELL Scientific Publication Corp., All rights reserved