Research Journal of Applied Sciences, Engineering and Technology

Using Photo Voltage Solar and Light Emitting Diodes to Reduce Energy Consumption: Case Study in Port Sudan City

Abstract

Port Sudan city is a capital of the Red Sea State in the republic of Sudan in south-eastern Africa. The city has high consumption of power for street lighting. The lighting is needed for 12 h/day. This consumes about 11.5 Mw day. The aim of this paper is study the proposed system to reduce the streetlight power consumption use in Port Sudan City and to explore the renewable energy to work alternative energy sources. The present paper studies the proposed system called (all-in-one) street lighting system consisting of PV panel, lithium ion battery and light sensor with LED lamp, all connected and constructed in single unit. The proposed system is to be used in Port Sudan city to decrease the electricity consumption, especially in summer. The problem has been treated theoretically. The proposed system has been compared with two types of plant the first plant used 250W lamp Ac and the second plant used 100W LED lamp. The results show that the proposed system has low cost, about 80 USD and much better economically. The proposed system can solve the power loss in Port Sudan city, saving 11.5 Mw day for this city and more than 428,000 SUP/day. The results show that the proposed system could be utilized to reduce lighting consumption, save energy and developments on environment. We therefore recommended to uses the proposed system in many countries not only in Port Sudan City.

Keywords:


Introduction

The green energy from wind, solar, biogas, hydro power and geothermal for world net electricity generation is expected to reach 36.5 trillion kWh in 2040. Electricity is the world’s fastest-growing form of end-use energy consumption, as it has been for many decades (EIA, 2016). Burning fossil fuel to produce electricity contributed about 40% of $CO_2$ to the environment. There are two ways to reduce these effects: one is to reduce the consumption of the energy and this solution is not applicable, the second is to reduce the pollution by finding alternative energy sources (IEA, 2003). Most of the countries are increasingly using renewable energy for electricity generation. Renewable and biomass technology are proposed to provide an efficient source of energy for electricity. Hydropower, renewable energy, bio power and geothermal energy are clean sources Renewable energy sources are clean, sustainable and environmental friendly. The current energy sources in Sudan are biomass, petroleum and hydropower (Omer, 2005). The best source of energy for lighting in Sudan at the present is hydropower. Although, wind and solar energy are the other suitable sources of energy for lighting. Utilization of these sources of energy for lighting applications will contribute in reducing indoor air pollution (Aghaei and Meisen, 2014).

The electricity load covers the residential sector (homes, schools and governmental buildings), community sector (streetlight and traffics signs) and the industrial sector. In some countries for many reasons as for touristic or safety reasons, the streetlight consumes a high load (Omer, 2002). The goal of this study is to reduce the streetlight power consumption use in Port Sudan City and to explore the renewable energy to work alternative energy sources.

Location: The power output depends on the wind speed, sun radiation and sun’s angle. These parameters depend on the location. According to NASA (NASA Agency, https://www.nasa.gov›news› releases ›), the sun’s rays are 40% as intense near the poles compared to that near the equator. Figure 1 shows Port Sudan irradiation during 12 months. The highest irradiation is in May, about 219 KWh/m2 and the lowest is in December, 123 KWh/m2 (El Mamoney and Khater, 2004).

Port Sudan: Port Sudan is the capital of the Red Sea State in eastern Sudan. Its location is (19.36526°N 37.13292°E) and 13 m above sea level. The population is estimated to be 579,942 people (Abdel Ati, 2000). Port Sudan climate is the Mediterranean Sea. The high temperature in summer about 48°C and in winter ranging from 21 to 30°C. The national grid supplies the town by electricity which is generates by hydro power and thermal power plants. Port Sudan has about 6000 street lighting lamps. This lamp take power >8 MW/day from the power provided by national grid by cost about 9000 SUP (Sudanese Pound) daily from the state treasury according to crop of city lighten (NEC, 2014). Port Sudan has high radiation hours about 3200 in year approximately, so we can use solar energy alternative resource for streetlight.

Street light system: Port Sudan city has a simple electric system for lighting the streets; the system contains a pole with total height of about 8 m and (30-35) m distance between every two poles, with 250 W nominal power phosphor with mercury lamps with total wire path 38.4 Km. In each sector there are number of counters to feed a certain number of poles (NEC, 2014).

Solar energy: Solar energy is divided into two forms Solar Photovoltaic (PV) and solar thermal system. Solar Photovoltaic (PV) system converts sunlight directly into electrical power, whereas solar thermal system utilizes sunlight for heating.

In rural, remote and off-grid areas, solar energy can be used in many applications such as: refrigeration, lighting, heating and cooking (Karekezi and Kithyoma, 2003). Sun shines in Port Sudan in the range of 9 h/day. Solar radiates on the horizontal surface in the range of 20.87 MJ/m2/day which is equivalent to insolation in the range of 5.8 kw h/m2/day.

Photovoltaic (PV) system consists of PV cells, battery, charger and inverter. The present PV cells are made of silicon crystalline material. The rated power of PV modules for energy applications generally range from several watts to 200W (Amogpai, 2007). PV systems can be grid connected or independent off-grid systems. Inverters and batteries are used in different applications in grid connected or off-grid areas. In grid connected system use inverter to convert Direct Current (DC) to Alternating Current (AC). In off-grid PV system can be used in rural, remote areas that lack electricity (Fujii et al., 2013).

Locating the sun’s position: The earth is rotating and changing location to the sun, so it is so important to locate the position of the cell according to the source of radiation (sun). In PV system, it is very important to direct the cells in such angle to the horizontal surface that gives the sunlight ability to fall into the module surface for maximum possible duration and intensity. The angle at which the module is inclined is called tilt angle (Bajpai et al., 2010). To determine the optimum tilt angle, it will be necessary to locate the position of the sun from the given site on the earth:

$ \text Declination\ angle\ of\ sun = 23.45*sin[360*\frac{284*N}{365}] ~~~~~~~~~~~~~~~~~~~~~~~~ (1)$

where,
N: The day number in the year (N = 1 for January 1 and N = 365 for December 31)

By using the equation above, the optimal array tilt angle can be determined for monthly adjustments, or for adjustments any time.

figure1
Fig. 1: Port Sudan irradiation (Boyce et al., 2009)

Literature Review

Using of solar energy in street light: In 2011 Electrical division MSME - Development institute, ministry of MSME, government of India contract a street light system in Agra city. The system is provided with battery storage backup sufficient to operate the light for 10-11 h daily. This system was provided with automatic on/off time switch for dusk to dawn operation and overcharge/deep discharge prevention cut-off with LED indicators (Panjang and Ulu, 2015).

In 2015 another team from Brunei National Energy Research Institute, constructed an off-grid PV lighting system (Panjang and Ulu, 2015).

In 11 may 2015 Kumar and Sudhakar (2015) published a paper about the performance of PV plant which produces about 10 Mw at location has nearly 3000 h of sun radiation and 50 acres (0.2 km2) of land. This plant is divided to eight areas or blockers with each two equal blocks. Each individual block has the generating capacity of about 625 Kw thus total of sixteen blocks combined to form a 10 Mw generation capacity. Each block of solar panels consists of about 230 strings each and a total of 1852 strings These large numbers of solar panels in single block are again divided into two blocks of strings. Each string consists of 24 solar panels connected in series and about 120 of these strings are connected in parallel to a single inverter through a main string combined box, every string have 24 module.


Results And Discussion

Modeling of the large PV plant: For designing Photovoltaic array or plant (PV system), we must calculate the energy consumed by the load in one day. The first step is to prepare a table of daily consumption of electrical energy by the applications to be powered by PV system.

The DC loads should be preferred over Ah loads to minimize the cost, no inverters cost, the energy loss and increase the system reliability.

The mathematical expression for the load calculation is:

$ \text Total\ average\ DC\ W\ h\ per\ day = \frac {Total\ Load} {7} ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (2)$

Table 1 shows load system which used for all sectors in city, which calculated by division the total average DC over the system voltage (Vs).

In Port Sudan the street light system has more than 3,800 lamps and growing. Those lamps consume more than 11500 Kw day throughout 12 h day.

This daily load consumes about 4197500 Kw (4.198 Gw year). This system like any system has different losses (wiring system, cap asters, inverters…), with a growing rate of many factors such as demographic and domestic tourism and also security factors. If, we assumption increasing of lamps is 600 lamps in all sectors for 2 years. The total of consuming will be nearly 13,300 Kw day in next 2 years; with an assumption the system losses are 15% the 15,295 Kw day and about 1,275 kWh.

Sizing of module/array: The important factor in the modeling is number of the modules which must be constructed and installed in the PV power plant (Ni0). Number of modules is counted according to the PV power plant rating (Pplant, num) in (W) divided to power of module (PM):

$ N_{i0} = (P_{plant,num})\ in\ (W)/PM $

$ N_{i0} = \frac {1,275,000} {345} = 3696\ module\ (pre - sizing) ~~~~~~~~~~~~~~~~~~~~~~~~ (3)$

There is many types of solar photovoltaic modules and cells, one of these modules is mono-crystalline, which generate 345 wh and this type can be suggested to be used in the proposed system. The number of modules can be calculated by using Eq. (4) as shown in Table 2 (multiply the number of module in factor 1.3 efficiency and growth rate is 1.2.

Figure 2 shows the calculation of consumption of all Sectors with 250W lamp:

$ Num\ module = \frac {Consume\ per\ kWh*1.3} {Module\ PW} ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (4)$

Figure 3 shows power sectors consummation details which obtaining from electricity ministry. The number of modules, the sizing of the battery and invertors, was changed in the calculation method.

Power calculation: The lamp was used in Port Sudan street light system lucalox-standard-tubular using mercury Content 16.434 mg and Light Center Length 158 mm from TUNGSRAMTM company made in Hungary. This type of lamp exported since the system established in the beginning of the 21st Century (Christian and Lestari, 2017).

The stabilizing thus produced a strong durable material, useful for fills in roads, buildings and other lightly loaded structures and also as a subgrade material for roads. The material withstood the worst simulated environment of severe prolonged flooding.

The eastern load and sizing calculations:
Load calculations: The total power is calculated by multiplying the total nominal power for the total lamps:

$ 250\ ×\ 1262\ lamp = 315.5\ Kw $

The total energy given by multiplies the total power consumed by the system to the operating hours which is (12 h):

$ Total\ energy = 3786\ Kwh $

In the proposed system mono-crystalline panel is used because of its high efficiency and high-power output, from AE solar German company. The panel data as shows in Table 3.

The total voltage and total current calculations at max power for the proposed system in eastern sector (as example):

$ Single\ module\ V_{MP}\ ×\ \text number\ of\ modules\ in\ series $

$ 39.34\ ×\ 4 = 157.36\ V $

$ Ampere = \text system\ power/voltage = 411/157.36 = 2.612A $

Number of modules in parallel can be found by dividing the current of the system to the $I_{MP}$:

$ 2612A/8.77 = 298\ module\ in\ parallel $

To make sure that our calculations is right we multiply the number of modules in series and number of the module in parallel:

$ 298\ ×\ 4 = 1190\ module $

Sizing of the battery: The best type of batteries for large PV solar system off grid is lithium ion (AES). This is because of high Depth of Discharge (DOD), high efficiency, long life (up to 15 years in 65% DOD), fast Charging 15% more than lead acid batteries and zero maintenance cost. The lithium battery has 10 years warranty with 7,300 USD price for each battery (Doughty and Roth, 2012). Table 4 and 5 shows the mechanical and electrical specification of the proposed battery.

Battery capacity sizing for eastern sector: The results were show in Table 2 the total load per Kw day is 3,792 Kw day for 1,262 lamps with 250 W nominal power. The calculations will be different according to type of the batteries:

$ \text The\ battery\ capacity\ calculation\ = $

$ ~~~~~~~Power(kW/day)\ ×\ EF_f\ ×\ DOD_f\ ×\ CR_f\ ×\ T_f = $

$ ~~~~~~~3792\ ×\ 1.05\ ×\ 1.25\ ×\ 1.05\ ×\ 1.08 = 5644\ kW/day ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (5)$

Anatomy and sizing of battery: The battery capacity has been calculated by dividing the total power consumed per day. The battery capacity over 48 V battery voltage multiplies (24) batteries in series (assumed) we will get 4900 amp/h. The dividing the system ampere hours to the maximum current of individual battery, this will give the number of batteries in parallel (38).

The total number of batteries is (912) battery, every individual battery has 6656W/h nominal energy. To make sure that the total batteries will cover the total energy of the system we can multiply the total number of batteries to the nominal energy of individual battery that give us (6,070,272 wh) which is little bigger than the total energy needed (5,644,000 wh) approximately, if we change the number of batteries in parallel to 36 battery the calculation will be (36×24×6,656) and giving about (5,750,784 wh) and that is enough.

Sizing of inverter: Photovoltage grid connected system use inverter to convert Direct Current (DC) to Alternating Current (AC). The inverter sizing depends on many factors such as power output from array and the rate of discharge of storage system. For the proposed system, can use DC lamp and Dispense from inverter, that means less structure and initial cost.

The simulation method (PV*SOL premium 2019 software version online simulation) has been suggested an inventor type called (Active energy storage GmbH inverter) and sized a 17 inverter for eastern sector. For the proposed system we suggested another inverter cheaper with high capacity and high warranty call (sunny island 4548-US) as shows in Fig. 4.

The sizing of Charge Regulator (CR): The Charge Regulator (CR) normally is used to protect the battery against over charge or deep discharge also to transfer the maximum available power from the PV array. By using another simulation program designed by ATLE Company, the eastern sector solar plant needs about 32517 amp h charge regulators with the number of 1131 solar panels.

For regulating the power from the panels to batteries with this load specification, Table 6, the suggested CR is 200 amps called Deming MPPT as shown in Fig. 5.

We need about 162 CR for the eastern region. Table 7 shows the quantities of main items in PV plant of all sectors and the approximated sizing.

The proposed street lighting system: Street lighting in any country follows certain standard. The European standard sets different lighting classes as a set of photometric requirements for different visual needs. The common street lighting classes according to this standard are ME, CE, S, A, ES and EV. The common light sources are categorized into incandescent lamps, fluorescent lamps, High Intensity Discharge (HID) lamps and Solid-State lamps (Amogpai, 2007).

The street lighting system load depends in general on the single lamp capacity. In Port Sudan the lamp which is used is phosphor type. It consumes about 3,000 W/day and the life time also is not preferable for working 12 h/day.

In these days, the factors, performance and low cost of High-Brightness (HB) LEDs will open a way for general lighting markets. LEDs have a good life time of range 100,000-50,000 h and burring life, about (4, 166, 7 day) or (11.44 years).

According to the EU street light specifications, which worked according to EU specifications in Alzbadani city in Syria, the system in Port Sudan matches the street light criteria, with pole height (8 m) and distance between two poles about (25-35) m.

With pole specifications (9 m high and 35 m distance between two poles), a 80 W LED used in 234 light unit with 9,600 Luminous in alzabdani city. With caution the system in Port Sudan using 28750 Luminous Hg-lamps with 251.6 W according to the manufacturing electrical sheet data, the luminous it's too much comparing with the EU standers. Table 8 shows the comparison of different lamps types and LED.

Figure 6 shows the relationship between pole height and covered area with the lux of the specific lamp according to EU standards for street lighting in 2004 (Christian and Lestari, 2017).

LED lamp: The Light-Emitting Diodes (LED) are diodes which emit white light. They are digital light based on the same technology as computer small chips.

LEDs have significant advantages over incandescent lamps such as: long life time, less energy consumption, high luminous efficacy, high consistency of color, no movable parts, also have low heat emitting and work under high temperatures nearly up to 80ºC (Boyce et al., 2009).

In the street lighting lamp structure, the manufacturers put a group of diodes light to get the specific luminous with low watt consumption. Figure 7 shows the LED lamp element structure which is suggested to be used in Port Sudan street lighting. It consists of:

  • Silicone lens
  • Phosphor plate
  • Transient voltage suppressor
  • Cathode
  • LED chip
  • Bond layer
  • Metal interconnect layer
  • Thermal bed
  • Ceramic substrate

We proposed LED lamp which has 10,000 luminous and long burning life up to 50,000 h of lighting and DC current, to be a replacement to 250 W lamp in Port Sudan street light system. It is made by Town light company with 5 years warranty from the company as shown in Fig. 8. Table 9 shows the LED lamp data.

Load calculation and module sizing: When we replace the lucalox-standard-tubular, which used in Port Sudan street light system who consumes about 250 W nominal power and use LED lamp with nominal power 100 w; this will reduce the load calculation rate to about 0.4.

The load calculation rate, number of solar module and batteries number are decreased, because using DC current that means no inverter is needed. The change in sizing details lead to minimizing the initial cost. The load calculation and module sizing for the proposed LED lamp for all sectors were shows in Table 10 and Fig. 9.

Anatomy and sizing of the eastern plant: The total energy needed from the plant is 164 Kwh that amount of energy need about 476 modules to meet the consumption, we should calculate the number of modules in series and parallel for area and layout of the plant.

The calculation for the eastern sector with 250 w mercury tubular is 1262 lamps. Table 9 shows the calculation for the anatomy with LEDs lamps the total consumption per hour (164 Kwh) and number of module (476), note that we approximate the total number of modules to an even number.

The change in total energy need to run the lighting system has an effect on the storage system (batteries) type, specification, number of batteries and construction anatomy (number of batteries in series and batteries in parallel). The results of batteries, modules anatomy and CR are show in Table 11.

Modern street light system: All-in-one system is a unit, which contains all items of solar lighting system (LED lamp, battery, wires…act); it’s an off-Grid system (standalone).

It has high burning hours, low power consumptions, high efficiency and absolutely no battery maintenance required for at least 3 to 4 years. Figure 10(a) and 10(b) show the items and structure of all in one system, which contains of mono-crystalline panel and controller linking it with lithium ion battery and a motion sensor, with others structure such as case with water proof and unit stand (Anand and Jain, 2015).

The proposed of all-in-one system: The selected all-in-one units match Port Sudan street lighting requirement and specification of pole height and distance. This unit has a 15,000 lm and 50,000 burning hours and water proof case with 80 USD price also with no maintenance for the 3 first years, as shown in Fig. 11.

Table 12 shows the quantities of lamps needed and price by USD for each type of plant, in spite of the third type (all in one) is a complete system (panel and battery and charge control. We will compare between the three systems. The results shown the same total price for the two type (plant with 250 w lamps and All in one type) because the single price for the 250 w the street light use now is the same price for the proposed all in one system (80$).

Technical filtrations: To filter the three types we should put some standards to select the best type, after the pre-study (economic and technical) base on the technical data sheets from the companies. The plant with 250 w AC lamps needs an inverter as we mentioned these inverters within the Balance of System (BOS) among with cabins and condition system and control system with other auxiliaries etc. The (BOS) takes rise up the total to (60-70%) of the solar off-grid storage systems, also increase maintains cost and the technical cost (installation and mounting and service) of the plant. The LED lamps consume 0.4 times than the 250 w lamps, with no need to investors that means less maintains and mounting also less (BOS) percentage cost (<60%), on the other side the All in one system more applicable and less technical support cost with easy installation cost.

figure2
Fig. 2: Consumption of all sectors with 250W lamp
figure3
Fig. 3: The power sectors consummation details
figure4
Fig. 4: The proposed inverter (sunny island inverter)
figure5
Fig. 5: CR deming MPPT
figure6
Fig. 6: Pole height and area relationship for Lux
figure7
Fig. 7: LED structure
figure8
Fig. 8: LED lamp
figure9
Fig. 9: Comparison load data for all sectors
figure10
Fig. 10: The structure of all in one system
figure11
Fig. 11: The proposed all in one unit
Table 1: An ampere hour or Ah loads for used system
Sector Total poles No. of lamps Consume Kw day
Eastern 627 1,062 3,186
Middle 1,092 1,200 3,600
Southern 883 1,560 4,680
Total 2602 3,822 11,466
Table 2: PV modules need for each sector
Sector No. of lamps Consume/Kwh Factor 1.3 Consume Kw day No. of module
Eastern 1,262 316 411 3,792 1,190
Middle 1,400 350 449 4,200 1,300
Southern 1,760 440 572 5,280 1,658
Total 4,422 1,106 1,462 13,272 4,148
Table 3: Panel data
Nominal power W 345
Open circuit voltage A 47.08
Voltage at max power VMP 39.34
Current at max power AMP 8.77
Operating temp. (ºC) -40 to +85
Dimensions (L×W×H, mm) 1956×992×40
Weight (Kg) 23.5
Price 115 USD
Table 4: Mechanical specifications
Length (A) 471.5 mm 18.5 in
Width (B) 347.5 mm 13.7 in
Height (C) 375 mm 14.7 in
Weight 87 kg 192 lb
Terminal M8
Terminal torque 6.64 ft-lb 9 Nm +/-3
Case material Steel
IR rating IP 55
Table 5: Electrical specifications
Nominal voltage 51.2 V
Charge voltage 54.4 V
Maximum voltage* 58.4 V
Minimum voltage 44.8 V
Nominal capacity (IC) 130 Ah
Nominal energy (IC) 6656 Wh
Max. continuous current 130 Adc
Peak current 300 Adc (3 sec)
Table 6: CR specification
Quick details
Place of origin Shandong (China) Brand name Deming
Model of number SCDC-48V200A Rated voltage 48V96V192V220V240V360V380V480V
Maximum current 200 A Application Solar system controller
Product name MPPT solar charge controller price for solar mppt power Charge mode MPPT maximum power point tracking
Warranty 1 year Display Display working status
System voltage 48 V Rated current 30A/40A/50A/60A/70A/80A/100A/200A
Type 3 stages mppt solar charge controller
Table 7: The quantities of main items in PV plant of all sectors
Sector No. of modules Number of batteries Number of inverter Number of CRs
Eastern 1,190 912 22 164
Middle 1,300 999 22 164
Southern 1,658 1,277 24 166
Table 8: Comparison of different lamps types and LED
Specifications LED High Pressure Sodium Vapor (HPSV) High pressure mercury vapor
Distance between poles 30 30 30
Number of poles 33 33 33
Investment ($) $$$ $$ $
Lamp wattage 70 w 150 w 250 w
System wattage 70 w 180 w 300 w
Luminous efficiency 90-130 Lm/W 100 Lm/W 60 Lm/W
System efficiency (Rapidly improving) 80 Lm/W 48 Lm/W
Watt per square meter 0.33 0.86 1.42
Lifetime 50k h 12k h 5k h
Annual energy consumption $1532 $3938 $6563
Hazardous substances No Yes Yes
Color Rendering Index (CRI) ˃70 25 ˂60
Table 9: LED lamp data
Name LED street light
Luminous 10.000
Burning life 50000 h
Nominal power 100 w
Origen place Jiangsu-China
Company Town light
Current DC
Table 10: Sector load and module data
Sector No. of lamp Consume/Kw h Factor 1.3 Kw h Consume/Kw day No. of module
Eastern 1,262 126.2 164.45 1,973 476
Middle 1,400 140.0 182.00 2,184 528
Southern 1,760 176.0 228.90 2,747 664
Total 4,422 442.2 576.29 6,807 1,668
Table 11: The eastern sector basic items quantities
Type Series Parallel Quantity Given Need
Modules 4 120 480 165.60 Kwh 164 Kwh
Batteries 12 28 312 209.60 Kw day 1968 Kw day
CR - 64 64 12.200 amps 12.190 amps
Table 12: The quantities of lamps needed for each type of plant
Sector Quantity needed Price by USD
Plant with 250 Watt AC lamp
Eastern 1,262 100,960
Middle 1,400 112,000
Southern 1,760 140,800
Total 4,422 353,760
Plant with 250 Watt LED lamp
Eastern 1,262 25,240
Middle 1,400 28,000
Southern 1,760 35,200
Total 4,422 88,400
All in one (one system)
Eastern 1,262 100,960
Middle 1,400 112,000
Southern 1,760 140,800
Total 4,422 353,760

Conclusion

Port Sudan city as capital for the red sea state and as touristic city consumes a large power for street light. The government of the state insures this power from the state treasury daily by feeding the electrometers to supply every group of pole lamp in the city streets. It cost about (3,390,996 SUP) yearly from the state treasury. The power supplied to operate the net of the street light is taken from the city share of power granted from the National Electricity Corporation (NEC). In the summer the consumption rises and the peak load get higher than the power granted. The streetlight system must be working from (6 pm to 6 am). The modern cities tend to reduce the power consumption for the community load such as street light and traffic light, traffic signal by supplying the power to them from renewable energy (especially solar). In this study we tried to select between three of solar power plant. The first option depends on using the old light system components such as the type of lamp used (250 w AC nominal power with 28,000 burning hours) and the same wires connections and calculated the load and PV solar sizing need to suit that consumption of energy during 12 h of operation. The calculations were very costly about (29 USD/watt) and 31 million American dollars initial cost, because the high power consumed by the lamp and the converting process from DC current of the panels to AC current of the used lamps, so it’s not practical and economical also. The lamps are major factor in the sensitivity analysis, because of their high nominal power. We proposed to change the lamps type with another type which has less nominal power and gives applicable specification to meet the street and poles design specification (pole height, distances between two poles) and also give appropriate illumines according to national specifications. We changed lamps by LED lamps with 100 W and much higher burning life (50,000 h). The calculations have shown reduced energy consumption by 60% than the first proposed plant and less initial cost, because no need for an inverter and their additional equipment with 12 million American dollar which is 60% less than the first proposed plant. With those two proposed systems to transform Port Sudan lighting system to solar lighting system with high initial cost. The proposed system chosen is called (All in one) street lighting system, this system is more applicable, no need highly trained workers, easy to construct, with minimum maintenance and long burning period (50,000 h) about 11.5 years operation. The proposed system cost about 398,090 SUP which can be restore by the government in 5 years after construction and saving about 428,000 USD (21,391,500 SUP) in the next 6 years. Developing of All in one system with LED lamps that suite a situation in street lighting system is extremely important. Government and research and academic institutions can play a role to provide these all in one with LED lamps as street lighting system. Research in the field of renewable energy technology in Sudan must be encouraged.


Author Details

1Mechanical Engineering Department, College of Engineering, Prince Sattam bin Abdulaziz University, Saudi Arabia

2Mechanical Engineering Department, Faculty of Engineering, Red Sea University, Port Sudan, 33311, Sudan

3Physics Department, Faculty of Applied Science, Red Sea University, Port Sudan, 33311, Sudan

4Physics Department, Faculty of Sciences, Sudan University of Science and Technology, Khartoum, 11116, Sudan


References

Abdel Ati, H., 2000. Internally Displaced People (IDPs) in Port Sudan Town, Red Sea State. A Report for Ockenden International, Sudan, November.
Aghaei, P. and P. Meisen, 2014. Solar Electric and Solar Thermal Energy: A Summary of Current Technologies. Global Energy Network Institute, November 2014, pp: 1-40.
Amogpai, A., 2007. Lighting and energy usage in Sudan. M.A. Thesis, Helsinki University of Technology, Espoo, Finland.
Anand, S. and N. Jain, 2015. Intelligent street light system using wireless Transmission: A review. Int. J. Adv. Res. Electron. Commun. Eng., 4(2).
Bajpai, P., V. Das and N.K. Kishore, 2010. Bi-annual sun tracking for solar PV module support structure: Study and implementation. Proceeding of 16th National Power Systems Conference, Dec. 15th-17th, 2010.
Boyce, P.R., S. Fotios and M. Richards, 2009. Road lighting and energy saving. Light. Res. Technol., 41: 245-260.
Christian, D. and P. Lestari, 2017. Lighting Technique and Lighting Layout. Artolite Grasindo. Basic Theory of Public Street Lighting Accessed Retrieved April 27, 2017.
Doughty, D.H. and E.P. Roth, 2012. A general discussion of Li Ion battery safety. Electrochem. Soc. Interface, 21(2): 37-44.
EIA (US Energy Information Admin.), 2016. International Energy Outlook 2016. Department of Energy (DoE), Washington, DC, USA, May, 2016.
El Mamoney, M.H. and A.E.M. Khater, 2004. Environmental characterization and radio-ecological impacts of non-nuclear industries on the Red Sea coast. J. Environ. Radioactiv., 73(2): 151-168.
Fujii, Y., N. Yoshiura, A. Takita and N. Ohta, 2013. Smart street light system with energy saving function based on the sensor network. Proceeding of the 4th International Conference on Future Energy Systems, pp: 271-272.
IEA (International Energy Agency), 2003. Renewable for Power Generation: Status and Prospects. 2003 Edn., OECD, Paris, France.
Karekezi, S. and W. Kithyoma, 2003. Operationalizing the NEPAD Energy Initiative. Renewable Energy in Africa. Novotel, Dakar, Senegal, June 2-4, 2003.
Kumar, B.S. and K. Sudhakar, 2015. Performance evaluation of 10 MW grid connected solar photovoltaic power plant in India. Energ. Reports, 1: 184-192.
NEC, 2014. National Electricity Corporation, Khartoum, Sudan, Executive Summary for Year 2014.
Omer, A.M., 2002. Overview of renewable energy sources in the Republic of the Sudan. Energy, 27: 523-547.
Omer, A.M., 2005. Biomass energy potential and future prospect in Sudan. Renew. Sust. Energ. Rev., 9(1): 1-27.
Panjang, R. and B. Ulu, 2015. Off-grid Solar PV Lighting Project System Sizing and Yield Analysis. Revision 1.1, February, 2015.

Rights and permissions

Open Access: This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third-party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/


Cite this Article

Received
Accepted
Published
November 18, 2019
February 25, 2020
June 15, 2020

DOI: http://doi.org/10.19026/rjaset.17.6043