Abstract
|
Article Information:
Pulse Charging of Nickel Cadmium Batteries for Lost Capacity Recovery
Ayodele O. Soge and Paul W. Lefley
Corresponding Author: Ayodele O. Soge
Submitted: July 01, 2011
Accepted: August 27, 2011
Published: December 01, 2012 |
Abstract:
|
This study presents an experimental investigation on the effectiveness of pulse recharging technique
in recovering the lost capacity of nickel cadmium batteries (NiCad), through a comparison test with the
conventional constant-current recharging technique. Scanning Electron Microscope (SEM) analysis has been
carried out on the electrodes of both pulse recharged and conventionally recharged NiCad cells after a
controlled experimental process to restore the lost capacity due to shallow cycling. The results show that the
pulse recharging technique performed equally well with the conventional recharging method in improving the
topologies of the cell electrodes and recovering the lost capacity of the NiCad cells. The causes of capacity loss
in NiCad batteries have also been investigated and the results obtained established the claim that shallow
cycling enhances large and dendritic crystalline growth on the cell electrodes.
Key words: Capacity loss, conventional charging, nickel cadmium batteries (NiCad), pulse charging, , ,
|