Abstract
|
Article Information:
Determination of Oil Life for Crane Liebherr LHM 500g Model 301 by Oil Condition Monitoring
H. Ahmadi and P. Salami
Corresponding Author: Payman Salami
Submitted: 2009 August, 05
Accepted: 2009 August, 28
Published: 2010 May, 10 |
Abstract:
|
The objective of this research is to choose and investigate the best oil replacement time by oil
condition monitoring for crane Liebherr LHM 500G model 301 that works near the sea in marine company.
This was achieved by investigating different oil sam ple analyses of crane Liebherr LHM 500G model 301. The
oil analysis was initially run under regular interval during machines life. Some series of tests were then
conducted under the operating hours of machine. Oil samples were regularly collected. Numerical data
produced by oil analysis were compared with another sample, in order to quantify the effectiveness of the
results of oil condition monitoring technique. The results from this paper have given more understanding on
the dependent and independent roles of oil analysis in predicting which oil is more suitable for working
machine condition. According to the results, the oil used in this crane can be used more than 130 h and the best
oil running time is 160 h.
Key words: Lubrication, machine condition monitoring, oil, oil analysis, oil time replacement, wear debris materials,
|