Abstract
|
Article Information:
Ground Investigation into the Hydro-Geotechnical Characteristics of a Municipal Waste Fill Using Static Cone Penetration Tests
Olayiwola A.G. Oni
Corresponding Author: Olayiwola Oni
Submitted: 2010 June, 13
Accepted: 2010 July, 03
Published: 2010 August, 01 |
Abstract:
|
This study describes the procedure used to undertake Cone Penetration Tests (CPTs) on the
municipal solid w aste landfill at W hite’s pit, Wimborne, UK. The results of the CPTs were interpreted and
analysed in the context of the usefulness of the tests for determining the geo-environmental properties of the
emplaced waste. The general hydro-physical characteristics of the emplaced w aste are comparable to sand/silt
mixtures, with no dynamic pore pressure. Although CPTs may not be appropriate for determining accurate
quantification of the hydro-physical properties of an emplaced waste, it may be suitable for a general
characterisation of the waste fill in relations to the soil type behaviour, especially at old sites with no historical
data of the type of materials that were emplaced. This finding will significantly enhance the decisions of geoenvironmental
engineers in field investigations concerning waste fills.
Key words: Cone penetration tests, landfill, friction ratio, characterisation, municipal waste, dynamic pore pressure,
|