Abstract:
|
This research was to study the internal flow patterns on heat transfer rates of the Horizontal Heat Mode Closed Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV). The HHMCLOHP/CV was made from a Pyrex glass capillary tube with a 2.4 mm inside diameter. There were 10 meandering turns with 2 check valves. Ethanol and a silver nano-ethanol mixture were used as working fluid. Experimental results found that if working fluid varies from ethanol to a silver nano-ethanol mixture and the evaporator temperature increases the main flow patterns were Slug flow + Annular flow. The main regime of each flow pattern can be determined from the flow pattern map.
Key words: Closed loop oscillating heat pipe, flow patterns, horizontal heat mode, , , ,
|
Abstract
|
PDF
|
HTML |
|
Cite this Reference:
S. Rittidech and S. Sangiamsuk, . Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV). Research Journal of Applied Sciences, Engineering and Technology, (03): 865-869.
|
|
|
|
|