Analysis of PD Pulses in Transmission Wire Line Network
1A. Natarajan and 2N. Suthanthiravanitha
1Department of ECE, Anna University, Chennai
2Department of EEE, Knowledge Institute of Technology, Salem, Tamil Nadu, India
Research Journal of Applied Sciences, Engineering and Technology 2016 4:415-419
Received: July 13, 2015 | Accepted: August 30, 2015 | Published: February 25, 2016
Abstract
The aim of study is to understand Partial discharge, in order to locate this phenomenon within an HV system. Voltages 110 kV and above are regarded as transmission level voltages. In long lines with light loads, lower voltages like 66 kV and 33 kV are frequently used. These lower voltages are known as sub transmission voltages. For distribution, voltages less than 33 kV are generally used. Voltages above 230 kV are regarded extra high voltage and above 765 kV are considered ultra high voltages. The equipment used at higher voltages is of different design when compared to the equipment used at lower voltages. It is necessary to design and develop a compact and cost effective insulation structure for a proper power transmission at higher voltages. Due to mechanical, thermal and electrical stress, the insulation may breakdown which leads to catastrophic failure of the device. Hence it is necessary for the users to have a warning device which gives advance notice about the potential insulation problems so that they may be repaired during a scheduled shutdown.
Keywords:
BPA, flashover, HV system, insulator, PD signal, S-Transform,
References
-
Gorur, R.S., H.M. Schneider, J. Cartwright, Y. Beausajour, K. Kondo et al., 2001. Surface resistance measurements on nonceramic insulators. IEEE T. Power Deliver., 16: 801-805.
CrossRef
-
Kumagai, S., B. Marungsri, H. Shinokubo, R. Matsuoka and N. Yoshimura, 2006. Comparison of leakage current and aging of silicone rubbers and porcelain in both field and salt-fog tests. IEEE T. Dielect. El. In., 13(6): 1286-1302.
CrossRef
-
Meyer, L.H., S.H. Jayaram and E.A. Cherney, 2004. Correlation of damage, dry band arcing energy and temperature in inclined plane testing of silicone rubber for outdoor insulation. IEEE T. Dielect. El. In., 11(3): 424-432.
CrossRef
-
Moghadam, M.K., J. Morshedian, M. Ehsani, M. Bahrami and H. Saddadi, 2013. Lifetime prediction of HV silicone rubber insulators based on mechanical tests after thermal ageing. IEEE T. Dielect. El. In., 20(3): 711-716.
CrossRef
-
Montoya, G., I. Ramirez and J.I. Montoya, 2004. Correlation among ESDD, NSDD and leakage current in distribution insulators. IEE P-Gener. Transm. D., 151(3): 334-340.
CrossRef
-
Shihua, Z., J. Xingliang, Z. Zhijing, H. Jianlin and S. Lichun, 2013. Flashover voltage prediction of composite insulators based on the characteristics of leakage current. IEEE T. Power Deliver., 28(3): 1699-1708.
CrossRef
-
Suwarno, M.I., 2006. Leakage current waveforms of outdoor polymeric insulators and possibility of application for diagnostics of insulator conditions. J. Electr. Eng. Technol., 1(1): 114-119.
Competing interests
The authors have no competing interests.
Open Access Policy
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Copyright
The authors have no competing interests.
|
|
|
ISSN (Online): 2040-7467
ISSN (Print): 2040-7459 |
|
Information |
|
|
|
Sales & Services |
|
|
|