The Relation of Performance Parameters for a 150K Auto-Cascade Refrigeration System
1XueLi Nie, 1Yang Shi, 1Zhang Bei and 2Wang Zhimin
1Department of Mechanical and Electrical Engineering, ZhengZhou University of Light Industry, ZhengZhou 450002, China
2Zhengzhou Great Wall Scientific Industrial and Trade Co. Ltd., ZhengZhou 450002, China
Research Journal of Applied Sciences, Engineering and Technology 2013 23:5461-5464
Received: December 07, 2012 | Accepted: January 19, 2013 | Published: May 28, 2013
Abstract
The performance parameters of a single compressed and four-stage segregating auto-cascade refrigeration system were developed in this study. The temperature of the cryogenic tank went down relatively slow with the evaporating temperature and the refrigerant temperature for W. When the state of system is steady, the suction pressure of the compressor is 0.3 MPa, the discharge pressure is decreased slowly. When the temperature of cryogenic tank is below zero 118°C, the discharge pressure is 1.34 MPa. The lowest temperature could reach-18°C and the refrigeration capacity was about 7 W.
Keywords:
Auto-cascade refrigeration system, mixture refrigerant, zeotropic,
Competing interests
The authors have no competing interests.
Open Access Policy
This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Copyright
The authors have no competing interests.
|
|
|
ISSN (Online): 2040-7467
ISSN (Print): 2040-7459 |
|
Information |
|
|
|
Sales & Services |
|
|
|