The Pumping Up Phenomenon of Double-Stage Bubble Pump with Water and Aqueous LiBr Solution

Hongtao Gao, Guotuan Ma and Wei Yang
Department of Refrigeration and Cryogenics Engineering, Dalian Maritime University, Dalian, 116026, China
Research Journal of Applied Sciences, Engineering and Technology  2013  6:2107-2112
http://dx.doi.org/10.19026/rjaset.5.4757  |  © The Author(s) 2013
Received: July 27, 2012  |  Accepted: September 03, 2012  |  Published: February 21, 2013

Abstract

The double-stage bubble pump, using thermal energy as driving force to transport the solution, can replace the mechanical solution pump in the double-effect lithium bromide absorption chiller. By building a bench, a lot of experimental research and analysis were conducted with water and different concentrations of lithium bromide solution as the working fluid of the bubble pump. The first-stage bubble pump in the experiment pumps up by the external heat source. The heat for driving the second-stage bubble pump is provided by refrigerant steam produced from the first-stage bubble pump. The experiment data shows that the heating of refrigerant vapor is only one of the elements of pump-up phenomenon. Another is that the intermediate solution flashes to vapor to become bubbles. The pump-up phenomenon of double-stage bubble pump has much to do with the pressure difference of intermediate solution and first-stage refrigerant vapor. With water as the working fluid, when the pressure difference between refrigerant vapor and the intermediate liquefied refrigerant is 3.5-3.9 kPa, the bubble pump can pump up and run for some time and the start-up time decreases with the driving head. When the working fluid is lithium bromide solution, the pressure difference of the double-stage bubble pump increases with the solution concentration and is bigger than that of water. The start-up time increases with the concentrations of lithium bromide solution within the range of 45.5 to 54% and decreases within the range of 54-59.5%. The start-up time is largest at 54% under this experimental condition. The experimental result is also compared with the single-stage bubble pump. The start-up time of double-stage bubble pump decreases with the driving height, which is contrary to the single-stage bubble pump.

Keywords:

Absorption refrigeration, double-stage bubble pump, pressure difference, pump-up phenomenon, startup time,


References


Competing interests

The authors have no competing interests.

Open Access Policy

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Copyright

The authors have no competing interests.

ISSN (Online):  2040-7467
ISSN (Print):   2040-7459
Submit Manuscript
   Information
   Sales & Services
Home   |  Contact us   |  About us   |  Privacy Policy
Copyright © 2024. MAXWELL Scientific Publication Corp., All rights reserved