Home            Contact us            FAQs
    
      Journal Home      |      Aim & Scope     |     Author(s) Information      |      Editorial Board      |      MSP Download Statistics

     Research Journal of Applied Sciences, Engineering and Technology


Improvised Energy Meter Supporting Wireless Data Transfer

1E. Aravind, 1G. Karthick, 1S. Harithaa, 1B. Ramya Sundaram and 2Shriram K. Vasudevan
1Department of Electrical and Electronics Engineering
2Department of Computer Science and Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, India
Research Journal of Applied Sciences, Engineering and Technology  2014  10:1266-1271
http://dx.doi.org/10.19026/rjaset.8.1094  |  © The Author(s) 2014
Received: June ‎17, ‎2014  |  Accepted: August ‎03, ‎2014   |  Published: September 15, 2014

Abstract

The purpose of the study is to design a prototype model of an energy meter which has the ability of wireless data transfer such as sending emails and SMS. In the current energy monitoring scenario, manual energy meter monitoring is a cumbersome and tedious process for the electricity boards. It involves huge manpower and higher expenditure for a simple task. Manual energy meter monitoring is highly erroneous and amounts to great losses for both the consumers and the electricity boards. In this conventional technique, losing the bills and delay in the arrival of the official to note down the reading are common affairs. Complete digitalization of bill delivery and transaction processes eliminates such uneventful circumstances. The manual reading method is inefficient to meet the raising power demands. The invention described here has the potential to wipe of manual energy meter reading from the scene and replace it with a sophisticated automated system facilitating remote monitoring of energy consumption. In this proposed system, the Raspberry Pi performs all the essential functions of a microcontroller and supports features like sending emails and SMS with the aid of Wi-Fi dongle and GSM modem. This automated system enables continuous monitoring of energy consumption.

Keywords:

Analog to Digital Converter (ADC) , Global System Monitoring (GSM), raspberry pi , Short Message Service (SMS) , Simple Mail Transfer Protocol (SMTP),


References

  1. Abhinandan, J., K. Dilip and K. Jyoti, 2012. Design and development of GSM based energy meter. Int. J. Comput. Appl., 47(12).
  2. Ananth, N., P. Bharath, K.V.J. Prakash and S. Vijetha, 2008. Wireless automated digital energy meter. Proceeding of the IEEE International Conference on Sustainable Energy Technologies (ICSET, 2008), Singapore, pp: 564-567.
  3. Bhupendra, S.C., 2013. Microcontrollers and its Applications. 1st Edn., SIPL, New Delhi, India.
    PMid:24381414    
  4. Feng, H. and Y. Percy, 2013. Implementation of a single-phase electronic watt-hour meter using the MSP430AFE2xx. Application Report SLAA494A, Texas Instruments Inc., Dallas.
  5. Kothari, D.P., K.V. Shriram, R.M.D. Sundaram and N. Murali, 2012. Embedded Systems. 1st Edn., New Age Publications, New Delhi, India.
  6. Matt, R. and W. Shawn, 2012. Getting Started with Raspberry Pi. 1st Edn., Shroff Publishers and Distributors Pvt. Ltd., Bangalore, India.
  7. Praveen, M.P., 2011. KSEB to Introduce SMS-based Fault Maintenance System. The Hindu News, Retrieved from: http://www.hindu.com (Accessed on: June 26, 2011).
    Direct Link
  8. Sawhney, A.K., 1987. A Course in Electrical and Electronic Measurements and Instrumentation. 5th Edn., Dhanpat Rai and Sons, Delhi, India.

Competing interests

The authors have no competing interests.

Open Access Policy

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Copyright

The authors have no competing interests.

ISSN (Online):  2040-7467
ISSN (Print):   2040-7459
Submit Manuscript
   Information
   Sales & Services
Home   |  Contact us   |  About us   |  Privacy Policy
Copyright © 2024. MAXWELL Scientific Publication Corp., All rights reserved